22 Laboratory Physical Containment (PC) Levels and Biological Safety Levels (BSL)
In this section:
Laboratory physical containment (PC) levels and biological safety levels (BSL) describe the degree of safety control required when working with microorganisms, viruses, or other biological materials that may cause infection. They are broadly equivalent classification systems, although different countries use different terminology. In Australia, the term “physical containment” level is used, whereas the United States of America (USA) commonly uses the term “biological safety level” (BSL). The World Health Organization (WHO) and many other international organisations use similar approaches to classify laboratory containment. Both PC and BSL systems use four levels, from Level 1 representing the lowest level of risk and containment, to Level 4 representing the highest.
These levels help determine the laboratory design, equipment, work practices, staff training, personal protective equipment, and access restrictions needed to prevent infectious agents from exposing laboratory workers or being released into the wider community. The appropriate level is determined by factors such as the organism’s ability to cause disease, the likely severity of disease, how easily it can be transmitted, whether infection could occur through inhalation, and whether effective treatments or vaccines are available. The type of work also matters. For example, procedures that generate aerosols, involve large culture volumes, or use concentrated infectious material may require additional precautions compared with routine handling of small samples.
PC or BSL level should not be confused with an organism’s Risk Group. A Risk Group describes the inherent hazard associated with a microorganism, including its ability to cause disease and the availability of prevention or treatment. By contrast, a PC or BSL level describes the practical containment measures required to work safely with that organism in a particular laboratory setting. In other words, Risk Group asks, “How hazardous is this organism?” whereas PC or BSL asks, “What laboratory protections are needed for this work?”. In many cases, higher Risk Group organisms require higher containment, but the final containment requirements must be based on a risk assessment that considers both the organism and the procedures being undertaken.

PC-1 (BSL-1) for Risk Group 1 Organisms
PC-1, also called BSL-1 in the United States, is the lowest containment level. It is used for organisms that are not known to cause disease in healthy adults and therefore pose very little risk to laboratory workers or the community. Examples include non-pathogenic laboratory strains of Escherichia coli (E. coli) and Bacillus subtilis, as well as baculoviruses, which are viruses that infect insects rather than humans.
Because the risk is low, work with PC-1 organisms can generally be undertaken on an open laboratory bench using standard microbiological techniques. Workers use aseptic technique to reduce contamination of cultures, samples, equipment, and the laboratory environment. Appropriate personal protective equipment may include a laboratory coat, gloves, and eye protection, depending on the procedure. A PC-1 laboratory generally requires basic features such as a handwashing sink and doors separating the laboratory from other areas of the building. More specialised containment systems are usually unnecessary, although equipment such as an autoclave may still be available for sterilising materials and waste.
PC-2 (BSL-2) for Risk Group 2 Organisms
PC-2, or BSL-2, is used for organisms that pose a moderate risk to laboratory personnel and the community. These organisms can cause human disease, but infection is generally preventable or treatable when appropriate laboratory controls are followed. They are often described as indigenous organisms because they may occur naturally within the local geographical area. Examples include Staphylococcus aureus, Salmonella species, and viruses that cause diseases such as hepatitis, mumps, and measles.
PC-2 laboratories require more safety controls than PC-1 laboratories. Access is restricted while infectious work is occurring, and workers must use appropriate personal protective equipment, which may include gloves, laboratory coats, eye protection, and face protection where there is a risk of splashes or sprays. Procedures that could produce aerosols, such as vortexing samples, pipetting infectious liquids, opening centrifuge tubes, or homogenising tissue, should be performed in a biological safety cabinet. A biological safety cabinet is a ventilated enclosure designed to reduce the release of potentially infectious aerosols and to protect the worker, laboratory environment, and, in some cases, the sample.
PC-2 laboratories commonly include self-closing doors, an eyewash station, and access to an autoclave. An autoclave sterilises equipment, cultures, and waste using pressurised steam before reuse or disposal. While PC-1 laboratories may also have access to an autoclave, its role is especially important in PC-2 work because infectious materials and contaminated waste require reliable decontamination.
PC-3 (BLS-3) for Risk Group 3 Organisms
PC-3, or BSL-3, is used for organisms that can cause serious or potentially fatal disease, particularly where infection may occur through inhalation. Inhalation is an important concern because small aerosol particles can remain suspended in air and may be breathed into the respiratory tract. PC-3 agents may be indigenous or exotic, meaning that they may originate locally or be introduced from another country or geographical region. Examples commonly associated with PC-3 work include Mycobacterium tuberculosis, Bacillus anthracis, West Nile virus, and certain work involving human immunodeficiency virus (HIV), although the containment level required for particular HIV activities depends on the procedures and risk assessment.
Because infection with PC-3 organisms can have serious consequences, entry to PC-3 laboratories is tightly controlled. Laboratory personnel must be specifically trained and authorised, and they may be subject to medical surveillance. Vaccination may also be required or recommended when an effective vaccine is available and appropriate for the work. In addition to standard laboratory clothing and personal protective equipment, respiratory protection may be needed. Infectious material is handled in a biological safety cabinet, particularly when there is any risk of producing aerosols.
PC-3 laboratories require specialised facility design features. These may include a hands-free handwashing sink, an eyewash station located close to the exit, and two sets of self-closing and locking doors that create a barrier between the laboratory and surrounding areas. The laboratory uses directional airflow so that air moves from cleaner areas towards the potentially contaminated laboratory space, rather than allowing laboratory air to flow outwards into corridors or other parts of the building. Laboratory air is not simply recirculated into general building areas; instead, the ventilation system is designed to reduce the likelihood that potentially contaminated air could leave the containment zone.
PC-4 (BSL-4) for Risk Group 4 Organisms
PC-4, or BSL-4, is the highest level of laboratory containment. It is used for the most dangerous infectious agents, particularly those that may cause severe or fatal disease, may be readily transmitted through inhalation, and may have no widely available treatment or vaccine. These organisms are often exotic rather than commonly found in the local community. Examples include Ebola virus and Marburg virus, which can cause severe viral haemorrhagic fevers, and variola virus, the virus responsible for smallpox.
PC-4 facilities use all the controls required at lower containment levels, together with the highest level of specialised engineering, procedural, and personal protection. Laboratory workers must be highly trained and authorised to enter the facility. They change into dedicated laboratory clothing before entry, shower before leaving the containment area, and ensure that all materials leaving the laboratory are thoroughly decontaminated. This includes waste, equipment, samples, protective clothing, and other materials that may have come into contact with infectious agents.
While working in a PC-4 laboratory, personnel either undertake their work in sealed, high-containment biological safety cabinets or wear a fully enclosed, positive-pressure protective suit with its own filtered air supply. A positive-pressure suit maintains a higher air pressure inside the suit than in the surrounding laboratory. If the suit is damaged or develops a leak, clean air flows outward through the opening, helping to prevent potentially contaminated laboratory air from entering the suit and being inhaled by the worker. (Figure 7.1).
The PC-4 laboratory itself must be physically separated or located in an isolated part of a building. It has dedicated systems for air supply, air exhaust, waste treatment, and decontamination. Air entering and leaving the laboratory is carefully controlled and filtered, while waste and materials are treated before they leave the facility. Australia has specialised PC-4 capacity for research and diagnostic work involving high-consequence infectious diseases, including facilities associated with the Doherty Institute. The Biological Safety Levels are summarised in Table 7.1.
Table 7.1 Biosafety levels summary
| Biological safety protocols | Description | Examples |
|---|---|---|
| PC-1 | Microbes are not known to cause disease in healthy hosts and pose minimal risk to workers and the environment | Risk Group 1: Non-pathogenic strains of Escherichia coli |
| PC-2 | Microbes are typically indigenous and are associated with diseases of varying severity. They pose moderate risk to workers and the environment | Risk Group 2: Staphylococcus aureus, Salmonella spp. Ross River virus, Rotavirus |
| PC-3 | Microbes are indigenous or exotic and cause serious or potentially lethal diseases through respiratory transmission | Risk Group 3: Mycobacterium tuberculosis, HIV, Lyssavirus, SARS CoV-2 |
| PC-4 | Microbes are dangerous and exotic, posing a high risk of aerosol-transmitted infections, which are frequently fatal without treatment or vaccines. Few laboratories are at this level. | Ebola, Hendra, Marburg viruses |
The lowest level of physical containment. PC1 facilities are suitable for work involving organisms that pose a low risk to human health and the environment. Work is conducted using standard laboratory practices and basic containment measures. Examples may include non-pathogenic laboratory strains of bacteria such as Escherichia coli K-12 or Bacillus subtilis.
A moderate level of physical containment used for work that requires additional controls to protect laboratory personnel and the environment. PC2 laboratories include specified facility requirements, equipment, work practices and procedures appropriate to the organisms or biological materials being handled.
A high level of physical containment used for work involving organisms or activities that present a greater risk and require stringent controls to prevent exposure or release. PC3 facilities use enhanced engineering controls, restricted access, specialised procedures and additional containment measures.
The highest level of physical containment. PC4 facilities provide the most stringent containment conditions for work presenting very high risks to human health or the environment. They incorporate highly specialised facility design, equipment, access controls and work practices to minimise the possibility of exposure or release.